Casement Windows China Supplier Air Leakage Comparison
Read the denominator before ranking an air-leakage number. Reconstruct total flow from its documented area or edge length, then keep test conditions and quotation applicability as separate review decisions.

Compare the Leakage Basis Before the Number
For casement windows from a China supplier, identify whether an air-leakage entry describes total flow, flow per window area or flow per defined edge length. A smaller raw number is not necessarily the lower result when its denominator differs. Reconstruct a common basis only from documented inputs and compatible conditions.
The RGNL-70 Thermal Break System Casement Window is the enquiry reference. Its existing specification and performance-document guide covers general evidence matching. This page adds a denominator calculation; it does not establish a leakage rating, certification or available testing service for that model.
Verified Product Starting Point
| Published RGNL-70 fact | Separate evidence question |
|---|---|
| 70 mm frame size | What specimen dimensions and area does the submitted result use? |
| 6063-T5 aluminum; 1.8 mm profile thickness | Does the record identify the quoted frame and sash assembly? |
| Double tempered insulating glass: 5 mm + 15A + 5 mm listed | Which exact glass and opening configuration was assessed? |
These construction entries identify the product, not measured airtightness. Do not convert profile width into a test area, infer a report from a product name, or transfer another series’ result to this quotation.
Three Expressions Describe Different Quantities
The DOE purchasing guidance distinguishes leakage reported per window area from reporting per linear foot of window edge. Preserve the complete unit, including the denominator, when transcribing an offer.
Using litres per second for our invented example, total flow Q has units L/s. An area-normalized entry qA has units L/(s m2); multiply by its documented area A to reconstruct Q. An edge-normalized entry qL has units L/(s m); multiply by the record’s defined length L. Thus Q = qA x A or Q = qL x L.
Obtain the stated denominator from the original record. A length might not mean the outside frame perimeter or every opening joint. Do not choose a convenient length from a photograph. Compatible flow units alone cannot resolve an undefined measurement boundary.
A Hypothetical Ranking Reversal
All values below are invented arithmetic, not RGNL-70 results, offered dimensions, production limits or project requirements. Assume the records concern comparable specimens, the same hypothetical 75 Pa pressure and compatible methods solely to isolate the denominator issue.
| Entry | Stated rate | Basis | Total Q |
|---|---|---|---|
| A: per area | 0.20 L/(s m2) | 1.50 m2 | 0.30 L/s |
| B: per edge | 0.08 L/(s m) | 5.00 m defined length | 0.40 L/s |
Although 0.08 is numerically below 0.20, B’s reconstructed total is larger: 0.08 x 5.00 = 0.40, versus 0.20 x 1.50 = 0.30. If B’s documented review area is also 1.50 m2, its equivalent area expression is approximately 0.267 L/(s m2).
That final division does not make B an NFRC rating or establish equivalence between real methods. It exposes why different denominators cannot be ranked by their bare numbers. Keep the original rate, denominator, arithmetic and reconstructed result together.
Stop When the Conditions Do Not Match
NFRC 400-2026 specifies window-area reporting and controlled test conditions. Its laboratory comparison is not a direct prediction of leakage in a particular installed building.
Keep pressure, direction, method, specimen size, opening arrangement and reported corrections beside each entry. If another return uses 300 Pa instead of the example’s 75 Pa, do not divide its flow by four or invent an exponent to force agreement. Request a comparable record or the responsible reviewer’s supported assessment.
Likewise, multiplying a tested rate by a larger ordered window’s area is not proof of that larger unit’s performance. Our reconstruction uses the record’s own denominator, not an extrapolation to a new size or configuration.
Control an OEM or ODM Evidence Change
For an OEM or ODM enquiry, assign responsibility for identifying the proposed assembly and returning the original evidence. Record changes to sash layout, seals, glass or hardware separately from a retyped number. Ask whether the earlier record remains applicable; do not treat unchanged marketing wording as confirmation.
Maintain three outcomes: arithmetic reproducible, conditions comparable, and evidence applicable to the quotation. These are buyer review decisions, not promises of development, certification or testing services. Preserve unresolved entries instead of inserting zero or silently excluding them.
Keep Evidence Work in the Quote Scope
Ask which existing records are available and whether requested clarification, assessment or additional testing needs a separately agreed scope, cost and responsible party. No laboratory fee, completion date or compliance outcome is promised here. Compare product prices after configuration and unresolved evidence boundaries are visible.
Return Inputs for a Checkable Comparison
- Window marks, quantities, proposed size, operation and drawing revision.
- Original leakage entry, full units, source page and report reference.
- Documented area or defined edge length, not an assumed perimeter.
- Pressure, direction, method, specimen configuration and any stated corrections.
- Separate arithmetic, comparability and applicability decisions, with owners.
Browse the Casement Windows range against the proposed scope. A complete calculation still needs the project reviewer’s evidence and acceptance decision.
Air-Leakage Comparison Questions
Is the smaller raw number always better?
No. Confirm whether it is total flow, an area-normalized rate or an edge-normalized rate before comparing it.
Can I assume edge length is the frame perimeter?
No. Use the definition and length in the supporting record, or request clarification.
Can a 300 Pa result be scaled to 75 Pa by division?
Not from this worksheet. Pressure normalization needs an applicable supported method, not an assumed linear shortcut.
Does the example verify RGNL-70 airtightness?
No. Every numerical leakage entry is hypothetical. Obtain model- and configuration-specific evidence for the actual quotation.
Request a Comparable Leakage Return
Send Rogenilan the exact window schedule and original evidence entries. Ask which configuration-specific records are available and resolve missing denominators before reviewing the quotation.